Concrete Surgeons is a sister company for Recap Engineering Solutions providing us the high-end chemical anchor products quality. As it’s the sole and the exclusive agents for CHEMOFAST in Egypt and North Africa.

CHEMOFAST one of the leading manufacturer of chemical anchor in the world wide. CHEMOFAST was founded in 1983 in Germany. With about 40 years, CHEMOFAST anchoring combines the knowledge and the experience to innovate a high quality chemical anchor products that fit with the different applications.

To guarantee the safety, CHEMOFAST ‘s products has been approved and certified by multiple organizations to meet all the standards fixed in the world.

EP 1000

Advantages:

  • Base: Pure Epoxy
  • Installation temperature from +5°C and a service temperature up to 72°C.
  • High chemical resistance for applications in extreme ambiences e.g. in swimming pools (chlorine) or closeness to the sea (salt).
  • With Seismic C1+C2 ETA approval

Applications:

  • Hammer drilled holes.
  • Cracked and uncracked concrete.
  • Seismic ETA C1 and C2.
  • Hollow drill bit.

Performance:

  • High Performance (Mechanical and thermal properties).

Resistance:

  • Fire Resistance & Chemical Resistance

Approvals:

  • European Assessment acc. to EAD 330499-01-0601 (Option 1, Annex E – TR 049, Seismic C1 and C2): ETA-19/0201 (M8-M30, ø8-32, C1+C2 M12-M24).
  • European Assessment acc. to EAD 330499-01-0601 (Annex C – Additional provisions for working life of 100 years): ETA-19/0201.
  • European Assessment acc. to EAD 330087-00-0601 (rebar): ETA-19/0200 (ø8-40mm; Hammer and Diamond drilling).
  • US-approval and Canada listing acc. to AC 308 in concrete (ICC-ES): ESR-4246, ELC-4011, ASTM C881.
  • Certificated for drinking water applications acc. to NSF Standard 61.
  • Fire resistance Test Report 21825, tests performed acc. to DIN EN 1363-1:2012 and Technical Report 020.

C-RE 385

Advantages:

  • Base: Epoxy Resins.
  • Installation temperature from +5°C and a service temperature up to 72°C
  • High chemical resistance for Epoxy Resins applications in extreme ambiences e.g. in swimming pools (chlorine) or closeness to the sea (salt).

Applications:

  • Preferably for anchoring reinforcing bars in concrete.
  • Ability to use in damp and water filled drill holes.
  • Usable in percussion drilled and diamond drilled holes.

Performance:

  • High Performance (Mechanical and thermal properties).

Resistance:

  • (Threaded rod) in hammer-drilled holes& Chemical Resistance.

Approvals:

  • European approval acc. to TR 029 in concrete Opt 1+7: ETA-09/0006 (M8-M30; ø8-32) incl. C1 + C2 Seismic.
  • European approval acc. to TR 029 in concrete (Diamond) Opt 7: ETA-11/0398 (M10-M24).
  • European approval acc. to TR 023 (rebar): ETA-12/0395 Rebar (Ø8-40), including Diamond drilled.
  • US-approval acc. to AC 308 in concrete (ICC-ES): ESR-2538.
  • Certificated for drinking water applications acc. to NSF Standard 61.
  • For heavy anchoring – doweling and post-installed rebar connection.
  • Fire resistance test report: 3302/252/08.
  • VOC Tests: acc. to Leed, French Décret n°2011-321; CA Section 01350; AgBB..

VK (Vinyl Ester)

Advantages:

  • Base: Vinyl ester resin, styrene-free.
  • Designed especially for the anchoring of threaded rods, reinforcing bars or internal threaded rod sleeves into concrete (also porous and light) as well as masonry.
  • Huge range of applications.
  • High chemical resistance for applications in extreme ambiences e.g. in swimming pools (chlorine) or in closeness to the sea (salt) with Category C1 (For seismic action). So it could be used in tropical climate.

Applications:

  • Particularly for heavy duty fastenings using threaded studs and reinforcing bars in concrete.
  • Usable in damp and water filled drill holes.

Performance:

  • Premium (Mechanical & Thermal properties and Chemical resistance).

Resistance:

  • Fire Resistance& Chemical Resistance.

Approvals:

  • European Technical Assessment acc. to ETAG 029 for use in masonry: ETA-16/0701 (15 international stones / 7 sleeves).
  • European Technical Assessment acc. to ETAG 001-5 for use concrete: ETA-08/0237 option 1+7 (M8-M30), including seismic.
  • European Technical Assessment acc. to ETAG 001-5 – TR 023 (rebar): ET A-09/0277 (Ø 8-32).
  • US-approval acc. to AC 308 in concrete (ICC-ES): ESR-2539.
  • Certificated for drinking water applications acc. to NSF Standard 61.
  • For heavy anchoring – doweling and post-installed rebar connection.
  • Fire resistance test report: EBB 170019-1 Overhead application; water filled bore holes